What Climate Zone is Yuma, Arizona?

Yuma is in IECC Climate Zone 2B (Hot - Dry). Get accurate Manual J load calculations with official design temperatures for Yuma.

Climate Zone
2B
Winter Design
31°F
Summer Design
108°F
ZIP Codes
12

Yuma, Arizona falls within IECC Climate Zone 2B (Hot - Dry), a cooling-dominated region with dry moisture conditions. HVAC contractors working in Yuma must use the official ASHRAE design temperatures of 31°F (99% winter) and 108°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 2B is cooling-dominated, solar heat gain control is critical. Yuma homes require windows with an SHGC of 0.25 or lower, along with R-13 wall insulation and R-30 ceiling insulation per the IECC 2021 energy code.

Yuma Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 2B in Yuma, Arizona.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Yuma HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2B requires precise load calculations. Upload your Yuma blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Yuma's exact design temperatures (31°F winter / 108°F summer).

Claim Free Report
No credit card required

Verify Your Yuma ZIP Code

Enter your ZIP code to confirm it's in Yuma and get climate zone details.

Yuma covers 12 ZIP codes: 85333, 85336, 85347, 85349, 85350, 85356, 85364, 85365, 85367, 85352 and 2 more

Yuma Design Temperatures

Official ASHRAE design temperatures for Yuma, used for accurate Manual J load calculations.

Winter 99% Design Temp
31°F
Summer 1% Design Temp
108°F
Summer Wet Bulb
71°F

IECC Requirements for Zone 2B

Minimum insulation and window requirements for Yuma per IECC 2021.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Yuma

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-90%

Cooling Systems

AC (14-16 SEER)
Evaporative cooling (swamp cooler)
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Yuma

Upload your Yuma blueprint and get a professional Manual J load calculation using official Zone 2B design temperatures. First report is FREE.

Yuma design temps
Zone 2B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report