What Climate Zone is La Paz, Arizona?

La Paz is in IECC Climate Zone 2B (Hot - Dry). Get accurate Manual J load calculations with official design temperatures for La Paz.

Climate Zone
2B
Winter Design
31°F
Summer Design
108°F
ZIP Codes
9

La Paz, Arizona falls within IECC Climate Zone 2B (Hot - Dry), a cooling-dominated region with dry moisture conditions. HVAC contractors working in La Paz must use the official ASHRAE design temperatures of 31°F (99% winter) and 108°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 2B is cooling-dominated, solar heat gain control is critical. La Paz homes require windows with an SHGC of 0.25 or lower, along with R-13 wall insulation and R-30 ceiling insulation per the IECC 2021 energy code.

La Paz Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 2B in La Paz, Arizona.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

La Paz HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2B requires precise load calculations. Upload your La Paz blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with La Paz's exact design temperatures (31°F winter / 108°F summer).

Claim Free Report
No credit card required

Verify Your La Paz ZIP Code

Enter your ZIP code to confirm it's in La Paz and get climate zone details.

La Paz covers 9 ZIP codes: 85325, 85328, 85334, 85344, 85346, 85348, 85357, 85359, 85371

La Paz Design Temperatures

Official ASHRAE design temperatures for La Paz, used for accurate Manual J load calculations.

Winter 99% Design Temp
31°F
Summer 1% Design Temp
108°F
Summer Wet Bulb
71°F

IECC Requirements for Zone 2B

Minimum insulation and window requirements for La Paz per IECC 2021.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for La Paz

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-90%

Cooling Systems

AC (14-16 SEER)
Evaporative cooling (swamp cooler)
Typical SEER
14-16 SEER