What Climate Zone is Cochise, Arizona?

Cochise is in IECC Climate Zone 3B (Warm - Dry). Get accurate Manual J load calculations with official design temperatures for Cochise.

Climate Zone
3B
Winter Design
35°F
Summer Design
99°F
ZIP Codes
28

Cochise, Arizona falls within IECC Climate Zone 3B (Warm - Dry), a mixed-climate region with dry moisture conditions. HVAC contractors working in Cochise must use the official ASHRAE design temperatures of 35°F (99% winter) and 99°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3B experiences both significant heating and cooling loads. Cochise homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Cochise Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3B in Cochise, Arizona.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Cochise HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3B requires precise load calculations. Upload your Cochise blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Cochise's exact design temperatures (35°F winter / 99°F summer).

Claim Free Report
No credit card required

Verify Your Cochise ZIP Code

Enter your ZIP code to confirm it's in Cochise and get climate zone details.

Cochise covers 28 ZIP codes: 85602, 85603, 85605, 85606, 85607, 85608, 85609, 85610, 85613, 85615 and 18 more

Cochise Design Temperatures

Official ASHRAE design temperatures for Cochise, used for accurate Manual J load calculations.

Winter 99% Design Temp
35°F
Summer 1% Design Temp
99°F
Summer Wet Bulb
68°F

IECC Requirements for Zone 3B

Minimum insulation and window requirements for Cochise per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Cochise

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Cochise

Upload your Cochise blueprint and get a professional Manual J load calculation using official Zone 3B design temperatures. First report is FREE.

Cochise design temps
Zone 3B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Cochise contractors who trust AutoHVAC